SYSCAL R2
Deep Resistivity/IP System

Syscal R2 resistivity meters
Features
-
Powerful Electrical Resistivity System
-
Entry Level IP System
-
Up to 1900 W Power
-
Output Current = 2.5A
-
Output Voltage = 1600V peak to peak
-
20 Bit A/D Converter
-
Compatible with Automated Electrode Switching System
General
A unique configuration places the R2 resistivity meter in a
class by itself. On one hand it is a powerful DC resistivity system that may be powered by
external 12V or motor generator. On the other it is a very portable, easy to use IP
system. In either mode it is a very accurate system featuring the Syscal resistivity meter
two channel design that permits simultaneous measurement of both voltage and current.
The R2 system consists of three components; the combined
transmitter/receiver unit; a DC/DC or AC/DC converter; and a power source, either 12 V
battery, or motor generator.
The transmitter/receiver features a noise monitoring system
for pre-induction control consisting of a DC digital voltmeter function. A line
check/ground resistance measurement allows the operator to check that all electrodes are
properly connected and grounded. Low pass analog filters reduce the effect of higher
frequency natural and cultural noise.
The R2 resistivity meters will monitor the input noise signal
between the two receiving electrodes so that noisy conditions may be noted. At the start
of each measurement the SP value is displayed. This value is also stored with each
reading. SP compensation is automatic, with linear drift correction, using digital
filtering. The SP value is recalculated at every third stack, which provides excellent
correction of the SP drift. electrical
resistivity
The R2 resistivity meters have automatic gain ranging for
both voltage and current. Digital stacking is used for noise reduction, with a maximum of
250 stacks. During stacking the operator can monitor either the instantaneous reading, or
the cumulative average value.
Resolution after stacking is 1µV. The standard deviation of
each reading is also displayed and stored. The R2 calculates apparent resistivity based on
the type of array and geometrical parameters that have been entered. Up to 1,000 readings
may be stored. Data transfer is by serial link.
In the frequency mode the R2 has an output waveform of ON+,
ON-. In the time domain mode, for resistivity and IP measurements, the waveform becomes
ON+, OFF, ON-, OFF. Pulse duration may be set from 0.25-10 seconds.
The IP effect may be measured in four windows whose width,
and delay time, may be programmed. The average value of the four chargeability windows is
calculated and displayed during measurement. At the end of the measurement the
chargeability for each window is displayed, and may be stored. Chargeability values
normalized with respect to a standard decay curve can be displayed for the detection of EM
coupling or noise effects.
The second component of a Syscal R2 electrical resistivity
system is the power converter. This may be either a DC/DC converter, or a motor generator
powered AC/DC converter. At the lower power range is a 125W DC/DC converter, powered by
external 12V. With a marginal increase in weight the next step up is a 250W DC/DC
converter that is still powered by a 12 V battery. The final step is a motor generator
powered AC/DC converter with maximum 1,200W output. The third component making up the
system is the power source itself, either 12V, or 220V; either battery or motor generator
supplied.
The Syscal R2 resistivity meter is truly a unique system able
to handle the deepest resistivity applications, to depths of 2,000 meters or more. It is
also a very portable IP system suitable for many shallow mineral exploration programs. The
R2 may be utilized with the Intelligent Node automated switching system.
Specifications
Power Sources
The Syscal R2 resistivity meters must be powered by an
external DC source for ground energization. Available sources:
A 125W DC/DC converter supplied by a 12V battery. Ranges: 50V
- 2.50A max, 100V -1.25A max, 200V -0.62A max, and 400V - 0.31 A max. Dimensions: 17 x 21
x 28cm. Weight: 4kg.
A 250W DC/DC converter supplied by a 12V battery. Ranges:
100V - 2.50A max, 200V 1.25A max, 400V -0.62A max, and 800V - 0.31 A max. Dimensions: 31 x
21 x 2 1 cm. Weight: 5kg.
A 1200W AC/DC converter supplied by a 220V (or 110V) motor
generator. Ranges: 50V - 1.5A max, 100V - 1.5A max, 200V - 1.5A max, 400V 1.5A max, and
800V -1.5A max. Dimensions: 43 x 29 x 32cm. Weight: 25kg.
Induced Polarization Measurements
Beyond apparent resistivity, the Syscal R2 resistivity meters
also measures electrical resistivity using the Time Domain Induced Polarization (IP)
parameter. The IP method is used in mineral exploration for the detection of massive and
scattered mineralization.
A pulse-current waveform is transmitted (ON+, OFF, ON-, OFF)
and the IP delay curve is analyzed with four changeability windows. The pulse duration (ON
time), the delay time and the width of each individual window are programmable. The
average value (M) of the four partial chargeabilities (Mi) is computed and displayed
during measurement, while the four Mi values are available after measurement.
resistivity meters
Chargeability values normalized with respect to a standard
decay curve can be displayed for the detection of EM coupling or noise effects. With this
versatile chargeability measurement, the Syscal R2 functions as both a resistivity meter
and a low-weight, low-cost IP system for shallow mineral exploration.
Measured Parameters
-
Measurement and display of current, voltage, standard
deviation, and SP
-
Computation and display of apparent resistivity for main
electrode arrays: Schlumberger, Wenner, Gradient, and dipole-dipole.
-
Measurement and display of IP chargeability with four
windows. Delay time and window widths individually programmable.
-
Display of noise level before measurement
-
Measurement and display of ground resistance (electrode
check)
Memory Operations
-
Storage of data in the internal memory: Up to 1022 readings.
Each reading includes current, voltage, SP, resistivity, chargeability, spacing, station
number, etc.
-
Reading of data stored in the memory on the LCD display
-
Transfer of data to a computer (ASCII, binary files) through
RS-232 serial link
-
Direct transfer of data to a printer
-
Remote control of the unit by a computer through the serial
link.
Transmitter
-
Maximum output voltage: 800V (1600V peak to peak)
-
Maximum Output Current: 2A (2.5A in option)
-
Maximum Output Power: 1600W (1900W in option)
-
External DC source for ground energization (DC/DC or AC/DC
converters)
-
Output Current Resolution: 10µA. Accuracy. Standard 0.3%,
max 1% from -20°C to + 70°C
-
Output Current Waveform: Frequency domain ON+, ON- for
resistivity. Time domain ON+, OFF, ON-, OFF for resistivity and chargeability. Pulse
duration (ON time) programmable from 0.25 to 10 s, with preset values of 0.5 s, 1 s and 2
s.
-
Thermal circuit breaker for overheating protection
-
Receiver:
-
Input Impedance: 10 Mohms
-
Input over voltage protection
-
Input Voltage Range: - 5V to + 5V
-
Automatic SP bucking (-5V to + 5V) with linear drift
correction up to 1 mV/s
-
50Hz and 60Hz power line rejection
-
Ground Resistance Measurement: 0.1 to 1,000k ohms
-
Voltage Measurement: Resolution: 1µV after stacking
-
A/D Converter: 20 Bit
-
Accuracy: Standard 0.3%, max 1% from -20°C to +70°C
-
Chargeability Measurement - Resolution: 0. 1mV/V Accuracy: 1%
of displayed value for a voltage greater than l0mv
-
Continuous digital stacking up to 250 stacks
Miscellaneous
-
LCD display of 2 lines of 20 characters
-
Weather-resistant case
-
Dimensions: 31 x 21 x 21cm
-
Weight: 6kg, including dry cells
-
Power supply for electronic circuits: Six
1.5V D size dry cells. Over 300 hours operation at 20°C
-
External DC source for ground energization (DC/DC or AC/DC
converters)
-
Operating Temperature Range: -20°C to +
70°C (Optionally -40°C to + 70°C)
-
Storage Temperature: -40°C to +80°C
Standard Components
Syscal R2 resistivity meter console, battery charger, data
transfer cable, software, transit case and instruction manual.
Ordering Information
|
Description
|
|
Order Number
|
|
Syscal R2 resistivity meter
|
|
500-190-0003
|
|
125W Converter
|
|
500-190-0006
|
|
250W Converter
|
|
500-190-0009
|
|
1,200W Converter
|
|
500-190-0012
|
|
Wenner Cable Set
|
|
500-190-0016
|
|
Multi Electrode System
|
|
500-190-0170
|
|
Sounding Cable Set
|
|
500-190-0160
|
|
2.5 Amp Upgrade
|
|
500-190-1132
|
|
 |
 |