SYSCAL R2
Deep Resistivity/IP System
Case History
Syscal R2 resistivity meters
Features
-
Powerful Electrical Resistivity System
-
Entry Level IP System
-
Up to 1900 W Power
-
Output Current = 2.5A
-
Output Voltage = 1600V peak to peak
-
20 Bit A/D Converter
-
Compatible with Automated Electrode Switching System
General
A unique configuration places the R2 resistivity meter in a class by
itself. On one hand it is a powerful DC resistivity system that may be
powered by external 12V or motor generator. On the other it is a very
portable, easy to use IP system. In either mode it is a very accurate
system featuring the Syscal resistivity meter two channel design that
permits simultaneous measurement of both voltage and current.
The R2 system consists of three components; the combined
transmitter/receiver unit; a
DC/DC or
AC/DC converter; and a power source, either 12 V battery, or motor
generator.
The transmitter/receiver features a noise monitoring system for
pre-induction control consisting of a DC digital voltmeter function. A
line check/ground resistance measurement allows the operator to check
that all electrodes are properly connected and grounded. Low pass analog
filters reduce the effect of higher frequency natural and cultural
noise.
The R2 resistivity meters will monitor the input noise signal between
the two receiving electrodes so that noisy conditions may be noted. At
the start of each measurement the SP value is displayed. This value is
also stored with each reading. SP compensation is automatic, with linear
drift correction, using digital filtering. The SP value is recalculated
at every third stack, which provides excellent correction of the SP
drift electrical resistivity.
The R2 resistivity meters have automatic gain ranging for both voltage
and current. Digital stacking is used for noise reduction, with a
maximum of 250 stacks. During stacking the operator can monitor either
the instantaneous reading, or the cumulative average value.
Resolution after stacking is 1µV. The standard deviation of each reading
is also displayed and stored. The R2 calculates apparent resistivity
based on the type of array and geometrical parameters that have been
entered. Up to 1,000 readings may be stored. Data transfer is by serial
link.
In the frequency mode the R2 has an output waveform of ON+, ON-. In the
time domain mode, for resistivity and IP measurements, the waveform
becomes ON+, OFF, ON-, OFF. Pulse duration may be set from 0.25-10
seconds.
The IP effect may be measured in four windows whose width, and delay
time, may be programmed. The average value of the four chargeability
windows is calculated and displayed during measurement. At the end of
the measurement the chargeability for each window is displayed, and may
be stored. Chargeability values normalized with respect to a standard
decay curve can be displayed for the detection of EM coupling or noise
effects.
The second component of a Syscal R2 electrical resistivity system is the
power converter. This may be either a DC/DC converter, or a motor
generator powered AC/DC converter. At the lower power range is a 125W
DC/DC converter, powered by external 12V. With a marginal increase in
weight the next step up is a
250W DC/DC
converter that is still powered by a 12 V battery. The final step is
a motor generator powered AC/DC converter with maximum 1,200W output.
The third component making up the system is the power source itself,
either 12V, or 220V; either battery or motor generator supplied.
The Syscal R2 resistivity meter is truly a unique system able to handle
the deepest resistivity applications, to depths of 2,000 meters or more.
It is also a very portable IP system suitable for many shallow mineral
exploration programs. The R2 may be utilized with the Intelligent Node
automated switching system.
Specifications
Power Sources
The Syscal R2 resistivity meters must be powered by an external DC source
for ground energization. Available sources:
A 125W DC/DC converter supplied by a 12V battery. Ranges: 50V - 2.50A max,
100V -1.25A max, 200V -0.62A max, and 400V - 0.31 A max. Dimensions: 17
x 21 x 28cm. Weight: 4kg.
A
250W DC/DC converter supplied by a 12V
battery. Ranges: 100V - 2.50A max, 200V 1.25A max, 400V -0.62A max, and
800V - 0.31 A max. Dimensions: 31 x 21 x 2 1 cm. Weight: 5kg.
A 1200W AC/DC converter supplied by a 220V (or 110V) motor generator.
Ranges: 50V - 1.5A max, 100V - 1.5A max, 200V - 1.5A max, 400V 1.5A max,
and 800V -1.5A max. Dimensions: 43 x 29 x 32cm. Weight: 25kg.
Induced Polarization Measurements
Beyond apparent resistivity, the Syscal R2 resistivity meters also
measures electrical resistivity using the Time Domain Induced
Polarization (IP) parameter. The IP method is used in mineral
exploration for the detection of massive and scattered mineralization.
A pulse-current waveform is transmitted (ON+, OFF, ON-, OFF) and the IP
delay curve is analyzed with four changeability windows. The pulse
duration (ON time), the delay time and the width of each individual
window are programmable. The average value (M) of the four partial
chargeabilities (Mi) is computed and displayed during measurement, while
the four Mi values are available after measurement. resistivity meters
Chargeability values normalized with respect to a standard decay curve can
be displayed for the detection of EM coupling or noise effects. With
this versatile chargeability measurement, the Syscal R2 functions as
both a resistivity meter and a low-weight, low-cost IP system for
shallow mineral exploration.
Measured Parameters
-
Measurement and display of current, voltage, standard deviation, and SP
-
Computation and display of apparent resistivity for main electrode
arrays: Schlumberger, Wenner, Gradient, and dipole-dipole.
-
Measurement and display of IP chargeability with four windows. Delay
time and window widths individually programmable.
-
Display of noise level before measurement
-
Measurement and display of ground resistance (electrode check)
Memory Operations
-
Storage of data in the internal memory: Up to 1022 readings. Each
reading includes current, voltage, SP, resistivity, chargeability,
spacing, station number, etc.
-
Reading of data stored in the memory on the LCD display
-
Transfer of data to a computer (ASCII, binary files) through RS-232
serial link
-
Direct transfer of data to a printer
-
Remote control of the unit by a computer through the serial link.
Transmitter
-
Maximum output voltage: 800V (1600V peak to peak)
-
Maximum Output Current: 2A (2.5A in option)
-
Maximum Output Power: 1600W (1900W in option)
-
External DC source for ground energization (DC/DC or AC/DC converters)
-
Output Current Resolution: 10µA. Accuracy. Standard 0.3%, max 1% from
-20°C to + 70°C
-
Output Current Waveform: Frequency domain ON+, ON- for resistivity. Time
domain ON+, OFF, ON-, OFF for resistivity and chargeability. Pulse
duration (ON time) programmable from 0.25 to 10 s, with preset values of
0.5 s, 1 s and 2 s.
-
Thermal circuit breaker for overheating protection
Receiver:
-
Input Impedance: 10 Mohms
-
Input over voltage protection
-
Input Voltage Range: - 5V to + 5V
-
Automatic SP bucking (-5V to + 5V) with linear drift correction up to 1
mV/s
-
50Hz and 60Hz power line rejection
-
Ground Resistance Measurement: 0.1 to 1,000k ohms
-
Voltage Measurement: Resolution: 1µV after stacking
-
A/D Converter: 20 Bit
-
Accuracy: Standard 0.3%, max 1% from -20°C to +70°C
-
Chargeability Measurement - Resolution: 0. 1mV/V Accuracy: 1% of
displayed value for a voltage greater than l0mv
-
Continuous digital stacking up to 250 stacks
Miscellaneous
-
LCD display of 2 lines of 20 characters
-
Weather-resistant case
-
Dimensions: 31 x 21 x 21cm
-
Weight: 6kg, including dry cells
-
Power supply for electronic circuits: Six 1.5V D size dry cells. Over
300 hours operation at 20°C
-
External DC source for ground energization (DC/DC or AC/DC converters)
-
Operating Temperature Range: -20°C to + 70°C (Optionally -40°C to +
70°C)
-
Storage Temperature: -40°C to +80°C
Standard Components
Syscal R2 resistivity meter console, battery charger, data transfer
cable, software, transit case and instruction manual.
Ordering Information
Description
|
|
Order Number
|
Syscal R2 resistivity meter
|
|
500-190-0003
|
125W Converter
|
|
500-190-0006
|
250W Converter
|
|
500-190-0009
|
1,200W Converter
|
|
500-190-0012
|
Wenner Cable Set
|
|
500-190-0016
|
Multi Electrode System
|
|
500-190-0170
|
Sounding Cable Set
|
|
500-190-0160
|
2.5 Amp Upgrade
|
|
500-190-1132
|